 . Overview

 This product is suitable for oil cycling lubricating system. Its working medium is turbine oil, No. 20~25 mechanical oil and steel rolling mill oil. The sporting viscosity grade is N22~N460 (equivalent to ISO VG22-460).

 The PN of lubricating oil station is 0.63MPa;  filtering accuracy is 0.08mm~0.12mm; temperature of cooling water ≤28°C; pressure of cooling water is 0.2~0.3MPa; feeding temperature of nger is 50°C ; the temperature decrease is 50°C; Vapor pressure at vapor heating is 0.2-0.4MPa.
 

 . Working principle

 The oil liquid discharged by oil pump is directly delivered to each lubricating point of device through one-way valve, double-cylinder netting filter and tube-type oil cooler. The highest supply pressure of lubricating oil station is 0.4MPa, and the lowest is 0.1MPa. Determine the pressure to use by adjusting the safety valve according to the requirements of lubricating points. When the working pressure exceeds the set pressure value of safety valve, the safety valve will automatically open, and the redundant oil liquid will flow back to oil tank. In normal running, one oil pump works and another is at standby. In the case that the oil consumption of device is required to be increased, the system pressure will decrease. When system pressure decreases to the set value, the standby pump will automatically start by adjusting the pressure regulator and work together with the working pump. The standby pump will automatically stop until the pressure returns to be normal. When system pressure decreases continuously and is lower than another set value, fault alarming signal will be sent by adjusting another pressure controller.

 A group of filtering elements of double-cylinder netting filter work and another group is at standby. There is a pressure difference signal sender at the inlet and outlet. When pressure difference is larger than 0.15MPa (≥250L/min, and 0.15~0.1MPa for lubricating oil station), the standby group of filtering elements will work by manual switching. Take out the original working filtering elements and wash or replace the filter.

 There is a pressure type electric contact gauge at the outlet of unit. The max and min limit values are set according to the requirements of oil temperature. When at low temperature, the signal light is on, and heater is turned on manually for heating. When oil temperature increases to the highest point, the heater will be cut off automatically and stop heating. When oil temperature is high, alarming will be sent and the cooler will be turned on.

 Lubricating oil station ≥250L/min. Lubricating oil in oil tank is heated by vapor. There is an additional instrument on the instrument board for detecting the pressure difference of water inlet and outlet pipelines of cooler. It key components are additionally installed on the base; while for lubricating oil station ≤250L/min, it’s all components are installed on the oil tank with an overall structure.
 

Ⅲ . Structural features

 a) Standby oil pump is equipped to ensure continuous oil supply to each lubricating point.

 b) Cooler is place in front of the filter to improve the capability of filtering and passing; it is more suitable for the lubricating medium with relatively higher viscosity.

 c) Double cylinder filter is employed so that filtering elements can be washed and replaced in the case of no stop.

 d) Tube-type oil cooler is employed which has good performance of cooling with low resistance and is convenient for repair.

 e) Magnetic screen filtering is employed at oil returning which can absorb and clear the iron particles in oil liquid so as to ensure the cleanness of oil liquid and extend the life of lubricating parts.

 f) Instrument board and electric control cabinet are equipped for observing the running parameters conveniently which may realize automated control and failure alarming.
 

 . Technical parameters

 Model

XYZ-6G

XYZ-10G

XYZ-16G

XYZ-25G

XYZ-40G

XYZ-63G

XYZ-100G

XYZ-125G

XYZ-250G

XYZ-400G

XYZ-630G

XYZ-1000G

Pressure (MPa)

≤0.4

Nominal flow (L/min)

6

10

16

25

40

63

100

125

250

400

630

1000

Output oil temperature (℃)

40±3

Volume of conservator (m³)

0.15

0.63

1

1.6

6.3

10

16

25

Filtering area (㎡)

0.05

0.13

0.19

0.4

0.52

0.83

1.31

2.2

Heat exchange area (㎡)

0.6

3

4

6

24

35

50

80

Consumption of cooling-water (m³/h)

0.36

0.6

1

1.5

3.6

5.7

9

11.25

12~22.5

20~36

30~56

60~90

Heater

Power (kW)

2

12

12

24

/

/

/

/

Voltage (V)

220

Consumption of steam (m³/h)

/

/

/

/

100

160

250

400

Motor

Model

JW7124-B5

Y90S-4-B5

Y100L1-4-B5

Y112M-4-B5

Y132S-4

Y132M-4

Y160L-4

Y180-4

Power (Kw)

0.55

1.1

2.2

4

5.5

7.5

15

22

Speed (r/min)

1400

1400

1430

1440

1440

1440

1460

1470

Weight (kg)

308

309

628

629

840

842

1260

1262

3980

5418

8750

12096


. Structure size



P 1-1-1 Types XYZ-6G~XYZ-125G lubricating oil station outline drawing


Model

DM

d

A

B

H

L

L1

L2

B1

B2

B3

E

B4

F

H1

H2

H3

H4

H5

H6

d1

XYZ-6G

25

G1/2”

700

550

450

890

190

20

255

220

742

213

150

0

800

550

268

80

268

380

G3/4”

XYZ-10G

XYZ-16G

50

G1”

1000

900

700

1371

256

30

410

363

1120

285

175

35

1120

855

350

130

350

580

G1”

XYZ-25G

XYZ-40G

50

G 1/4”

1200

1000

850

1545

235

30

470

390

1244

290

248

60

1360

990

355

160

355

740

G1”

XYZ-63G

XYZ-100G

80

G1 1/2”

1500

1200

950

2198

390

32

560

444

1400

305

170

100

1500

978

355

180

375

820

G1 1/4”

XYZ-125G


P 1-1-2 Types XYZ-250G~XYZ-1000G lubricating oil station outline drawing



     Model

Oil return’s DN

Oil out’s DN

Water in&out’s DN

A

B

H

A1

A2

A3

A4

A5

XYZ-250G

125

65

65

3300

1600

1200

4295

442

100

560

945

XYZ-400G

150

80

100

3600

2000

1500

4655

492

100

572

800

XYZ-630G

200

100

100

4300

2600

1600

5900

560

170

750

1445

XYZ-1000G

250

125

200

5300

2600

1900

7360

630

235

1285

2000

Model

B1

B2

B3

B4

B5

B6

H1

H2

H3

H4

Steam interface

XYZ-250G

3225

2355

570

364

1960

300

2172

1600

1050

1850

G1”

http://www.langolubrication.com/